Model Number |
HG 3612 |
BG 4820 |
BG 6020 |
BG 7220 |
220V |
Electricl Requirments |
1-Ph, 5 Amps, 60Hz |
3-Ph, 10 Amps, 60Hz |
3-Ph, 10 Amps, 60Hz |
3-Ph, 10 Amps, 60Hz |
Minimum Circuit Amps |
10 Amps |
20 Amps |
20 Amps |
20 Amps |
Maximum Fuse Size |
10 Amps |
20 Amps |
20 Amps |
20 Amps |
|
Overall Length |
12 feet (366 cm) |
20 feet (606 cm) |
20 feet (606 cm) |
20 feet (606 cm) |
Heated Oven Length |
6 feet (183 cm) |
11 feet (335 cm) |
11 feet (335 cm) |
11 feet (335 cm) |
Conveyor Infeed |
2 feet (61 cm) |
4 feet (122 cm) |
4 feet (122 cm) |
4 feet (122 cm) |
Conveyor Delivery |
2 feet (61 cm) |
3 feet (91 cm) |
3 feet (91 cm) |
3 feet (91 cm) |
Fume Hoods - Each End |
1 foot (30.5 cm) |
1 foot (30.5 cm) |
1 foot (30.5 cm) |
1 foot (30.5 cm) |
Frame Width |
48 inches (122 cm) |
60 inchs (152 cm) |
72 inches (183 cm) |
84 inches (213 cm) |
Overall Width (control box and air plenum box installed) |
55 inches (140 cm) |
89 inchs (226 cm) |
101 inches (256 cm) |
113 inches (287 cm) |
Height (floor to top of exhaust) |
69 inches (175 cm) |
83-1/2 inchs (212 cm) |
83-1/2 inches (212 cm) |
83-1/2 inches (212 cm) |
Belth Height From Floor |
34 inches (86 cm) |
34 inch (86 cm) |
34 inches (86 cm) |
34 inches (86 cm) |
Belth Width |
36 inches (91 cm) |
48 inchs (122 cm) |
60 inches (152 cm) |
72 inches (183 cm) |
|
Belt Type |
TCF (Teflon Coated Fiberglass) |
TCF (Teflon Coated Fiberglass) |
TCF (Teflon Coated Fiberglass) |
TCF (Teflon Coated Fiberglass) |
Belt Speed |
0 - 17 FPM (0 - 5 m/min) |
0 - 17 FPM (0 - 5 m/min) |
0 - 17 FPM (0 - 5 m/min) |
0 - 17 FPM (0 - 5 m/min) |
Belt Speed Control |
Analog Knob 0-10 |
Analog Knob 0-10 |
Analog Knob 0-10 |
Analog Knob 0-10 |
Temperature Control |
Digital (with Hi/Low temp alarm) |
Digital (with Hi/Low temp alarm) |
Digital (with Hi/Low temp alarm) |
Digital (with Hi/Low temp alarm) |
Oven Temperature Accuracy |
+/-5F (2C) of set point |
+/-5F (2C) of set point |
+/-5F (2C) of set point |
+/-5F (2C) of set point |
|
Maximum Oven Temperature |
400F (204C) |
400F (204C) |
400F (204C) |
400F (204C) |
Minimum Oven Temperature |
250F (120C) |
250F (120C) |
250F (120C) |
250F (120C) |
BTU Input Minimum |
39,000 BTU |
100,000 BTU |
100,000 BTU |
100,000 BTU |
BTU Input Maximum |
85,000 BTU |
300,000 BTU |
300,000 BTU |
300,000 BTU |
|
Exhaust Airflow |
450 CFM - 10 inch Duct (12,600 1/min - 25 cm duct) |
1,300 CFM - 14" duct (36,400 1/min - 35 cm duct) |
1,300 CFM - 14inch Duct (36,400 1/m - 35 cm duct) |
1,300 CFM - 14" duct (36,400 1/min - 35 cm duct) |
Exhaust Air Motors |
1/10 H.P. direct drive |
1/2 H.P. direct drive |
1/2 H.P. Direct Drive |
1/2 H.P. direct drive |
|
Recirculating Airflow |
1,000 CFM Fixed |
2,600 CFM Fixed |
2,600 CGM Fixed |
2,600 CFM Fixed |
Recirculating Air Motors |
1 H.P. |
Two 1 H.P. direct drive AC 3-phase motors |
Two 1 H.P. Direct Drive AC 3-Phase Motors |
Two 1 H.P. direct drive AC 3-phase motors |
|
Air Filters |
Fume Hood (None)
Combustion Air (None)
Recirculation Air (1) |
Fume Hood (4)
Combustion Air (1)
Recirculation Air (2) |
Fume Hood (4)
Combustion (1)
Recirculation (2) |
Fume Hood (4)
Combustion Air (1)
Recirculation Air (2) |
Minimum Distances To Other Surfaces For Installation
(suitable for use on Non-Combustible flooring only) |
Back |
18 inchs (46 cm) |
18 inchs (46 cm) |
18 inches (46 cm) |
18 inchs (46 cm) |
Ends |
40 inchs (102 cm) |
40 inchs (102 cm) |
40 inches (102 cm) |
40 inchs (102 cm) |
Front |
48 inchs (122 cm) |
48 inchs (122 cm) |
48 inches (122 cm) |
48 inchs (122 cm) |
Flue To Surface |
18 inchs (46 cm) |
18 inchs (46 cm) |
18 inches (46 cm) |
18 inchs (46 cm) |
|
Indicator Lamps |
Interlocks Proven
Purging
Burner On |
Interlocks Proven
Purging
Burner On |
Interlocks Proven
Purging
Burner On |
Interlocks Proven
Purging
Burner On |
|
Interlocks |
High Temp Limit
Exhaust Purge Proving
Recirculation Proving (1)
Combustion Air Proving |
Emergency Stop
High Gas Pressure
Low Gas Pressure
Exhaust Purge Proving
Recirculating Proving (2)
Combustion Air Proving
High Temp Limit |
Emergency Stop
High Gas Pressure
Low Gas Pressure
Exhaust Purge Proving
Recirculation Proving (2)
Combustion Air Proving
High Temp Limit |
Emergency Stop
High Gas Pressure
Low Gas Pressure
Exhaust Purge Proving
Recirculating Proving (2)
Combustion Air Proving
High Temp Limit |
|
Flameguard (flame proving) |
Honeywell S87K Ignition Control |
Eclipse Flame Pack |
Eclipse Flame Pack |
Eclipse Flame Pack |
|
Safety Standards |
Built to ANSI Z21.17 |
Built to UL-795 |
Built to UL-795 |
Built to UL-795 |
|
Gas Type Requirments |
Natural Gas |
Natural Gas |
Natural Gas |
Natural Gas |
Gas Pressure Requirments |
0.25 PSI / 7inch Water Column |
1.0-5.0 PSI (0.1-0.3 bar) |
1.0-5.0 PSI (0.1-0.3 bar) |
1.0-5.0 PSI (0.1-0.3 bar) |
Gas Service Inlet |
3/4inch NPT |
3/4inch NPT |
3/4inch NPT |
3/4inch NPT |
(Units made for Propane Gas available on special order) |
Gas Pressure Propane |
0.5 PSI / 34mbar |
0.5 - 3.0 PSI
(0.05 - 0.22 bar) |
0.5 - 3.0 PSI
(0.05 - 0.22 bar) |
0.5 - 3.0 PSI
(0.05 - 0.22 bar) |
Per Hour Consumption Estimate at 350F / 175C (at idle) |
Electic |
0.58 KWH |
2.5kW |
2.5kW |
2.5kW |
Gas |
0.053 mcf |
0.12 MCF |
0.13 MCF |
0.14 MCF |
In US$(electic @ $0.10/kWh; gas @ $6.50/MCF |
$0.40 per hour |
$1.03 |
$1.10 |
$1.16 |