HIX Corporation

Drying Equipment > Gas Dryers

HG/BG

HG BG Gas Dryers
     

HG© Overview               HG Manual

HG-3612 is the most energy efficient gas convection-air conveyor dryer on the market today. The 36" x 12' belt/chamber configuration features and 85,000 BTU burner that tops out at 400 degrees. Equipped with a single speed air system this dryer eliminates harmful fumes from cured inks and substrates while efficiently recirculating oven chamber heat to improve efficiency. Drying times are easily set with an analog belt speed controller which works in conjunction with the digital temperature controller which allows the temperature to stay within a 5 degree set point range. Safety switches control temperature, combustion recirculation and exhaust to allow for continuous worry free operation. Built for easy maintenance the 3612 filters are easily accessible for cleaning after removing top accessible panels.


Click here to view the HIX HG3612 Information Flyer


BG© Overview            BG Manual

The HIX GasAir features the latest in gas convection-air technology conveyor dryer system. Built for efficiency and high production comes in 48, 60, and 72 inch configurations. All sizes feature an efficient 300,00 BTU burner in conjunction with fresh air combustion to recirculate oven chamber heat.

Equipped with a single speed air system this dryer eliminates harmful fumes from cured inks and substrates. Drying times are easily set with an analog belt speed controller which works in conjunction with the digital temperature controller. Temperature are set to stay within a 5 degree set point range. Safety switches control temperature, combustion recirculation and exhaust to allow for continuous worry free operation. Built for easy maintenance the GasAir filters are easily accessible for cleaning after removing top accessible panels.

Model Number HG 3612 BG 4820 BG 6020 BG 7220
220V
Electricl Requirments 1-Ph, 5 Amps, 60Hz 3-Ph, 10 Amps, 60Hz 3-Ph, 10 Amps, 60Hz 3-Ph, 10 Amps, 60Hz
Minimum Circuit Amps 10 Amps 20 Amps 20 Amps 20 Amps
Maximum Fuse Size 10 Amps 20 Amps 20 Amps 20 Amps
 
Overall Length 12 feet (366 cm) 20 feet (606 cm) 20 feet (606 cm) 20 feet (606 cm)
Heated Oven Length 6 feet (183 cm) 11 feet (335 cm) 11 feet (335 cm) 11 feet (335 cm)
Conveyor Infeed 2 feet (61 cm) 4 feet (122 cm) 4 feet (122 cm) 4 feet (122 cm)
Conveyor Delivery 2 feet (61 cm) 3 feet (91 cm) 3 feet (91 cm) 3 feet (91 cm)
Fume Hoods - Each End 1 foot (30.5 cm) 1 foot (30.5 cm) 1 foot (30.5 cm) 1 foot (30.5 cm)
Frame Width 48 inches (122 cm) 60 inchs (152 cm) 72 inches (183 cm) 84 inches (213 cm)
Overall Width (control box and air plenum box installed) 55 inches (140 cm) 89 inchs (226 cm) 101 inches (256 cm) 113 inches (287 cm)
Height (floor to top of exhaust) 69 inches (175 cm) 83-1/2 inchs (212 cm) 83-1/2 inches (212 cm) 83-1/2 inches (212 cm)
Belth Height From Floor 34 inches (86 cm) 34 inch (86 cm) 34 inches (86 cm) 34 inches (86 cm)
Belth Width 36 inches (91 cm) 48 inchs (122 cm) 60 inches (152 cm) 72 inches (183 cm)
 
Belt Type TCF (Teflon Coated Fiberglass) TCF (Teflon Coated Fiberglass) TCF (Teflon Coated Fiberglass) TCF (Teflon Coated Fiberglass)
Belt Speed 0 - 17 FPM (0 - 5 m/min) 0 - 17 FPM (0 - 5 m/min) 0 - 17 FPM (0 - 5 m/min) 0 - 17 FPM (0 - 5 m/min)
Belt Speed Control Analog Knob 0-10 Analog Knob 0-10 Analog Knob 0-10 Analog Knob 0-10
Temperature Control Digital (with Hi/Low temp alarm) Digital (with Hi/Low temp alarm) Digital (with Hi/Low temp alarm) Digital (with Hi/Low temp alarm)
Oven Temperature Accuracy +/-5F (2C) of set point +/-5F (2C) of set point +/-5F (2C) of set point +/-5F (2C) of set point
 
Maximum Oven Temperature 400F (204C) 400F (204C) 400F (204C) 400F (204C)
Minimum Oven Temperature 250F (120C) 250F (120C) 250F (120C) 250F (120C)
BTU Input Minimum 39,000 BTU 100,000 BTU 100,000 BTU 100,000 BTU
BTU Input Maximum 85,000 BTU 300,000 BTU 300,000 BTU 300,000 BTU
 
Exhaust Airflow 450 CFM - 10 inch Duct (12,600 1/min - 25 cm duct) 1,300 CFM - 14" duct (36,400 1/min - 35 cm duct) 1,300 CFM - 14inch Duct (36,400 1/m - 35 cm duct) 1,300 CFM - 14" duct (36,400 1/min - 35 cm duct)
Exhaust Air Motors 1/10 H.P. direct drive 1/2 H.P. direct drive 1/2 H.P. Direct Drive 1/2 H.P. direct drive
 
Recirculating Airflow 1,000 CFM Fixed 2,600 CFM Fixed 2,600 CGM Fixed 2,600 CFM Fixed
Recirculating Air Motors 1 H.P. Two 1 H.P. direct drive AC 3-phase motors Two 1 H.P. Direct Drive AC 3-Phase Motors Two 1 H.P. direct drive AC 3-phase motors
 
Air Filters Fume Hood (None)
Combustion Air (None)
Recirculation Air (1)
Fume Hood (4)
Combustion Air (1)
Recirculation Air (2)
Fume Hood (4)
Combustion (1)
Recirculation (2)
Fume Hood (4)
Combustion Air (1)
Recirculation Air (2)
Minimum Distances To Other Surfaces For Installation
(suitable for use on Non-Combustible flooring only)
Back 18 inchs (46 cm) 18 inchs (46 cm) 18 inches (46 cm) 18 inchs (46 cm)
Ends 40 inchs (102 cm) 40 inchs (102 cm) 40 inches (102 cm) 40 inchs (102 cm)
Front 48 inchs (122 cm) 48 inchs (122 cm) 48 inches (122 cm) 48 inchs (122 cm)
Flue To Surface 18 inchs (46 cm) 18 inchs (46 cm) 18 inches (46 cm) 18 inchs (46 cm)
 
Indicator Lamps Interlocks Proven
Purging
Burner On
Interlocks Proven
Purging
Burner On
Interlocks Proven
Purging
Burner On
Interlocks Proven
Purging
Burner On
 
Interlocks High Temp Limit
Exhaust Purge Proving
Recirculation Proving (1)
Combustion Air Proving
Emergency Stop
High Gas Pressure
Low Gas Pressure
Exhaust Purge Proving
Recirculating Proving (2)
Combustion Air Proving
High Temp Limit
Emergency Stop
High Gas Pressure
Low Gas Pressure
Exhaust Purge Proving
Recirculation Proving (2)
Combustion Air Proving
High Temp Limit
Emergency Stop
High Gas Pressure
Low Gas Pressure
Exhaust Purge Proving
Recirculating Proving (2)
Combustion Air Proving
High Temp Limit
 
Flameguard (flame proving) Honeywell S87K Ignition Control Eclipse Flame Pack Eclipse Flame Pack Eclipse Flame Pack
 
Safety Standards Built to ANSI Z21.17 Built to UL-795 Built to UL-795 Built to UL-795
 
Gas Type Requirments Natural Gas Natural Gas Natural Gas Natural Gas
Gas Pressure Requirments 0.25 PSI / 7inch Water Column 1.0-5.0 PSI (0.1-0.3 bar) 1.0-5.0 PSI (0.1-0.3 bar) 1.0-5.0 PSI (0.1-0.3 bar)
Gas Service Inlet 3/4inch NPT 3/4inch NPT 3/4inch NPT 3/4inch NPT
(Units made for Propane Gas available on special order)
Gas Pressure Propane 0.5 PSI / 34mbar 0.5 - 3.0 PSI
(0.05 - 0.22 bar)
0.5 - 3.0 PSI
(0.05 - 0.22 bar)
0.5 - 3.0 PSI
(0.05 - 0.22 bar)
Per Hour Consumption Estimate at 350F / 175C (at idle)
Electic 0.58 KWH 2.5kW 2.5kW 2.5kW
Gas 0.053 mcf 0.12 MCF 0.13 MCF 0.14 MCF
In US$(electic @ $0.10/kWh; gas @ $6.50/MCF $0.40 per hour $1.03 $1.10 $1.16